Water Quality Report · Updated May 12, 2026
JONESBORO WATER SYSTEM
JONESBORO WATER SYSTEM delivers tap water graded C (71/100) by TapWaterSafety.org. The utility serves approximately 79,889 residents in JONESBORO, Arkansas using groundwater. The most significant water quality concerns are: Total trihalomethanes (TTHMs) significantly above health guideline; Dibromoacetic acid significantly above health guideline; Haloacetic acids (HAA9) significantly above health guideline. For questions, the utility can be reached at 870-926-9142.
Is JONESBORO tap water safe to drink?
JONESBORO WATER SYSTEM delivers tap water that earns a grade of C (71/100) from TapWaterSafety.org — an average rating, with several contaminants above health guidelines but generally compliant with US legal limits.
The utility serves 79,889 residents in JONESBORO, drawing from groundwater.
Public testing data identifies 11 contaminants in this water above EWG's health-based guidelines, including: Total trihalomethanes (TTHMs), Dibromoacetic acid, Haloacetic acids (HAA9), Chromium (hexavalent), Haloacetic acids (HAA5), Dibromochloromethane, Bromodichloromethane, Nitrate, Nitrate and nitrite, Bromoform, Radium, combined (-226 and -228). For most residents, a properly certified home filter at the kitchen tap is the most cost-effective way to reduce exposure to whatever's in your water. See our filter recommendations below, matched specifically to this utility's contaminant profile.
Quick actions for JONESBORO residents
Top concerns in this water
Based on the most recent EPA and EWG data, these are the most significant water quality issues for JONESBORO WATER SYSTEM.
Total trihalomethanes (TTHMs) significantly above health guideline
Moderate concernTotal trihalomethanes (TTHMs) detected at 7.85 ppb, 52x above the EWG health guideline of 0.15 ppb.
Dibromoacetic acid significantly above health guideline
Moderate concernDibromoacetic acid detected at 1.24 ppb, 41x above the EWG health guideline of 0.03 ppb.
Haloacetic acids (HAA9) significantly above health guideline
Moderate concernHaloacetic acids (HAA9) detected at 2.19 ppb, 37x above the EWG health guideline of 0.06 ppb.
Contact JONESBORO WATER SYSTEM
Reach the utility directly for service issues, water quality concerns, or to request your Consumer Confidence Report.
General Contact
Treatment Plant
Recommended water filters for JONESBORO
Filters matched to the specific contaminants in this water supply.
Carbon block (NSF/ANSI 42 + 53)
$40-$750Activated carbon is highly effective for disinfection byproducts like TTHM and HAA5.
Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.
Score breakdown
This utility's overall score of 71/100 breaks down across five weighted components. Read the full methodology →
Contaminants detected — international standards comparison
Every contaminant detected, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal (the strictest US benchmark). Why we show multiple standards →
| Contaminant | Detected | EWG US health-based |
EPA US legal |
EU DWD Europe |
WHO global |
CA PHG strictest US |
Tested sample year |
Status |
|---|---|---|---|---|---|---|---|---|
| Total trihalomethanes (TTHMs) Disinfection byproduct |
7.85 ppb | 0.15 | 80.0 | 100 | — | — | — | 52× over |
| Dibromoacetic acid Disinfection byproduct |
1.24 ppb | 0.03 | — | — | — | — | — | 41× over |
| Haloacetic acids (HAA9) Disinfection byproduct |
2.19 ppb | 0.06 | — | — | — | — | — | 37× over |
| Chromium (hexavalent) Heavy metal |
0.395 ppb | 0.02 | — | — | — | — | — | 20× over |
| Haloacetic acids (HAA5) Disinfection byproduct |
1.03 ppb | 0.1 | 60.0 | 60 | — | — | — | 10× over |
| Dibromochloromethane Disinfection byproduct |
0.935 ppb | 0.1 | — | — | — | — | — | 9.3× over |
| Bromodichloromethane Disinfection byproduct |
0.45 ppb | 0.06 | — | — | — | — | — | 7.5× over |
| Nitrate Inorganic |
0.792 ppm | 0.14 | 10.0 | 11.3 | 11.3 | 10 | — | 5.7× over |
| Nitrate and nitrite Inorganic |
0.53 ppm | 0.14 | 10.0 | 11.3 | 11.3 | 10 | — | 3.8× over |
| Bromoform Disinfection byproduct |
1.86 ppb | 0.5 | — | — | — | — | — | 3.7× over |
| Radium, combined (-226 and -228) Radiological |
0.19 pCi/L | 0.05 | 5.0 | — | — | — | — | 3.7× over |
| Chloroform Disinfection byproduct |
0.276 ppb | 0.4 | — | — | — | — | — | Below guideline |
| Chlorate Disinfection byproduct |
17.0 ppb | 210.0 | — | — | — | — | — | Below guideline |
| Vanadium Other |
0.295 ppb | 21.0 | — | — | — | — | — | Below guideline |
| Manganese Heavy metal |
0.578 ppb | 100.0 | — | 50 | 80 | — | — | Below guideline |
| Xylenes (total) Volatile organic compound |
2.99 ppb | 1800.0 | 10000.0 | — | — | — | — | Below guideline |
| Strontium Radiological |
0.0374 ppb | 1500.0 | — | — | — | — | — | Below guideline |
| Fluoride Inorganic |
0.769 ppm | — | 4.0 | 1.5 | 1.5 | — | — | Below guideline |
| Naphthalene Other |
0.0302 ppb | — | — | — | — | — | — | Below guideline |
All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.
Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines (4th ed.), California OEHHA PHGs, EWG Tap Water Database.
JONESBORO WATER SYSTEM service area
This water system serves 1 community in Poinsett County, Arkansas. Click any city for its dedicated tap water quality page.
Find the right filter for JONESBORO water