Free tap water grades for 1,100+ water systems & 10,000+ ZIP codesFree tap water grades for 10,000+ ZIP codes Official EPA compliance records · Independent ratings

Tap Water Quality Report

Tap water quality in Chula Vista, California

Served by SWEETWATER AUTHORITY. 191,282 residents.

Average score 68/100
Utilities 1
Population 191,282
D
68/100
Below Average
ⓘ How did we get this rating?
Quick answer

Tap water in Chula Vista, California receives a grade of D (68/100) from TapWaterSafety.org. It's served by SWEETWATER AUTHORITY. The most significant water quality concerns are: Haloacetic acids (HAA9) significantly above health guideline; Haloacetic acids (HAA5) significantly above health guideline; Total trihalomethanes (TTHMs) significantly above health guideline; Arsenic detected. Data sources: EPA SDWIS, EPA ECHO, EWG Tap Water Database.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?

What's in Chula Vista's tap water

Top water quality concerns identified by the EPA and Environmental Working Group across the utility serving Chula Vista.

Haloacetic acids (HAA9) significantly above health guideline

Moderate concern

Haloacetic acids (HAA9) detected at 30.0 ppb, 500x above the EWG health guideline of 0.06 ppb.

Haloacetic acids (HAA5) significantly above health guideline

Moderate concern

Haloacetic acids (HAA5) detected at 36.2 ppb, 362x above the EWG health guideline of 0.1 ppb.

Total trihalomethanes (TTHMs) significantly above health guideline

Moderate concern

Total trihalomethanes (TTHMs) detected at 39.3 ppb, 262x above the EWG health guideline of 0.15 ppb.

Arsenic detected

Moderate concern

Arsenic detected at 0.524 ppb.

EPA compliance record

Official U.S. EPA records for SWEETWATER AUTHORITY (system ID CA3710025) for the last 3 years. Checked 2026-10-07.

No EPA violations in the last 3 years.
0 of 12quarters with a violation
Nolead above EPA action level
11/22/2023last state inspection

Source: U.S. EPA Enforcement and Compliance History Online (ECHO), from the Safe Drinking Water Information System. See EPA's full report.

Recommended filters for Chula Vista

Filters matched to the specific contaminants in Chula Vista's water supply.

Carbon filter certified for VOCs (NSF/ANSI 53)

$180-$599

Activated carbon is effective for disinfection byproducts. Look for NSF/ANSI 53 VOC reduction.

Aquasana AQ-5300 Under-Sink Filter
$180-$240 NSF 42, 53, 401, 372
Editorial pick · affiliate link coming soon
AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, 372
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401
Editorial pick · affiliate link coming soon

Reverse osmosis certified for arsenic (NSF/ANSI 58)

$429-$599

Reverse osmosis certified under NSF/ANSI 58 for arsenic is the most reliable home option.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, 372
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401
Editorial pick · affiliate link coming soon

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

All contaminants detected in Chula Vista's tap water

Every contaminant identified, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal. Why we show multiple standards →

Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Haloacetic acids (HAA9)
Disinfection byproduct
30.0 ppb 0.06 — — — — — 500× over
Haloacetic acids (HAA5)
Disinfection byproduct
36.2 ppb 0.1 60.0 60 — — — 362× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
39.3 ppb 0.15 80.0 100 — — — 262× over
Dibromoacetic acid
Disinfection byproduct
7.42 ppb 0.03 — — — — — 247× over
Bromodichloromethane
Disinfection byproduct
11.7 ppb 0.06 — — — — — 195× over
Dibromochloromethane
Disinfection byproduct
13.7 ppb 0.1 — — — — — 137× over
Arsenic
Heavy metal
0.524 ppb 0.004 10.0 10 10 0.004 — 131× over
Dichloroacetic acid
Disinfection byproduct
8.73 ppb 0.2 — — — — — 44× over
Trichloroacetic acid
Disinfection byproduct
1.96 ppb 0.1 — — — — — 20× over
Chloroform
Disinfection byproduct
7.05 ppb 0.4 — — — — — 18× over
Bromoform
Disinfection byproduct
6.85 ppb 0.5 — — — — — 14× over
Uranium
Radiological
1.13 pCi/L 0.43 20.0 30 30 0.43 — 2.6× over
Chromium (hexavalent)
Heavy metal
0.0343 ppb 0.02 — — — — — 1.7× over
Chlorate
Disinfection byproduct
275.1 ppb 210.0 — — — — — 1.3× over
Nitrate and nitrite
Inorganic
0.0576 ppm 0.14 10.0 11.3 11.3 10 — Below guideline
Nitrate
Inorganic
0.0502 ppm 0.14 10.0 11.3 11.3 10 — Below guideline
Manganese
Heavy metal
21.7 ppb 100.0 — 50 80 — — Below guideline
Vanadium
Other
4.08 ppb 21.0 — — — — — Below guideline
Bromochloromethane
Other
0.0112 ppb 0.06 — — — — — Below guideline
Molybdenum
Other
4.32 ppb 40.0 — — — — — Below guideline
Barium
Heavy metal
33.1 ppb 700.0 2000.0 — 1300 2000 — Below guideline
Aluminum
Heavy metal
21.1 ppb 600.0 — 200 — 600 — Below guideline
Selenium
Heavy metal
0.337 ppb 30.0 50.0 20 40 30 — Below guideline
Monobromoacetic acid
Disinfection byproduct
0.087 ppb 25.0 — — — — — Below guideline
Strontium
Radiological
0.684 ppb 1500.0 — — — — — Below guideline
Bromide
Other
208.9 ppb — — — — — — Below guideline
Fluoride
Inorganic
0.507 ppm — 4.0 1.5 1.5 — — Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines, California OEHHA PHGs, EWG Tap Water Database.

Treatment plant contact info

For service issues, water quality concerns, or to request a Consumer Confidence Report from SWEETWATER AUTHORITY.

Treatment Plant

FacilityREYNOLDS DESALTER

ZIP codes served

Chula Vista's public water systems serve the following ZIP codes: