Free tap water grades for 1,100+ water systems & 10,000+ ZIP codesFree tap water grades for 10,000+ ZIP codes Official EPA compliance records · Independent ratings

Tap Water Quality Report

Tap water quality in Santa Ana, California

Served by CITY OF SANTA ANA. 310,539 residents.

Average score 47/100
Utilities 1
Population 310,539
Quick answer

Tap water in Santa Ana, California receives a grade of F (47/100) from TapWaterSafety.org. It's served by CITY OF SANTA ANA. The most significant water quality concerns are: PFAS contamination; Perfluorohexane sulfonate (PFHXS) significantly above health guideline; Haloacetic acids (HAA5) significantly above health guideline; Arsenic significantly above health guideline. Data sources: EPA SDWIS, EPA ECHO, EWG Tap Water Database.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?

What's in Santa Ana's tap water

Top water quality concerns identified by the EPA and Environmental Working Group across the utility serving Santa Ana.

PFAS contamination

Severe concern

Perfluorononanoic acid (PFNA), Perfluorooctane sulfonate (PFOS) detected. PFAS are persistent chemicals linked to cancer and immune effects with no known safe exposure threshold.

Perfluorohexane sulfonate (PFHXS) significantly above health guideline

Moderate concern

Perfluorohexane sulfonate (PFHXS) detected at 2.67 ppt, 2667x above the EWG health guideline of 0.001 ppt.

Haloacetic acids (HAA5) significantly above health guideline

Moderate concern

Haloacetic acids (HAA5) detected at 36.2 ppb, 362x above the EWG health guideline of 0.1 ppb.

Arsenic significantly above health guideline

Moderate concern

Arsenic detected at 0.507 ppb, 127x above the EWG health guideline of 0.004 ppb.

EPA compliance record

Official U.S. EPA records for CITY OF SANTA ANA (system ID CA3010038) for the last 3 years. Checked 2026-10-07.

No EPA violations in the last 3 years.
0 of 12quarters with a violation
Nolead above EPA action level
03/27/2024last state inspection

Source: U.S. EPA Enforcement and Compliance History Online (ECHO), from the Safe Drinking Water Information System. See EPA's full report.

Recommended filters for Santa Ana

Filters matched to the specific contaminants in Santa Ana's water supply.

Filter certified for PFOA/PFOS (NSF/ANSI 53 or 58)

$180-$750

Reverse osmosis and some carbon block filters reduce PFAS. Look for certification to NSF/ANSI 53 or 58 for PFOA/PFOS.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, 372
Editorial pick · affiliate link coming soon
Aquasana AQ-5300 Under-Sink Filter
$180-$240 NSF 42, 53, 401, 372
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401
Editorial pick · affiliate link coming soon
Waterdrop G3P800 Tankless RO
$600-$750 NSF 42, 53, 58, 372
View on retailer →

Carbon filter certified for VOCs (NSF/ANSI 53)

$180-$599

Activated carbon is effective for disinfection byproducts. Look for NSF/ANSI 53 VOC reduction.

Aquasana AQ-5300 Under-Sink Filter
$180-$240 NSF 42, 53, 401, 372
Editorial pick · affiliate link coming soon
AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, 372
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401
Editorial pick · affiliate link coming soon

Reverse osmosis certified for arsenic (NSF/ANSI 58)

$429-$599

Reverse osmosis certified under NSF/ANSI 58 for arsenic is the most reliable home option.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, 372
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401
Editorial pick · affiliate link coming soon

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

All contaminants detected in Santa Ana's tap water

Every contaminant identified, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal. Why we show multiple standards →

Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Perfluorooctane sulfonate (PFOS)
PFAS
4.33 ppt 0.3 4.0 100 100 1 — EPA violation
Perfluorohexane sulfonate (PFHXS)
PFAS
2.67 ppt 0.001 10.0 — — — — 2667× over
Haloacetic acids (HAA5)
Disinfection byproduct
36.2 ppb 0.1 60.0 60 — — — 362× over
Arsenic
Heavy metal
0.507 ppb 0.004 10.0 10 10 0.004 — 127× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
18.5 ppb 0.15 80.0 100 — — — 123× over
Bromodichloromethane
Disinfection byproduct
5.5 ppb 0.06 — — — — — 92× over
Haloacetic acids (HAA9)
Disinfection byproduct
4.99 ppb 0.06 — — — — — 83× over
Dibromochloromethane
Disinfection byproduct
5.39 ppb 0.1 — — — — — 54× over
Chromium (hexavalent)
Heavy metal
0.985 ppb 0.02 — — — — — 49× over
Dibromoacetic acid
Disinfection byproduct
1.29 ppb 0.03 — — — — — 43× over
Perfluorooctanoic acid (PFOA)
PFAS
2.96 ppt 0.09 4.0 100 100 0.007 — 33× over
Trichloroacetic acid
Disinfection byproduct
2.33 ppb 0.1 — — — — — 23× over
Chloroform
Disinfection byproduct
6.08 ppb 0.4 — — — — — 15× over
Dichloroacetic acid
Disinfection byproduct
3.08 ppb 0.2 — — — — — 15× over
Nitrate
Inorganic
1.73 ppm 0.14 10.0 11.3 11.3 10 — 12× over
Nitrate and nitrite
Inorganic
1.69 ppm 0.14 10.0 11.3 11.3 10 — 12× over
Uranium
Radiological
2.71 pCi/L 0.43 20.0 30 30 0.43 — 6.3× over
Perfluorononanoic acid (PFNA)
PFAS
0.028 ppt 0.006 10.0 — — — — 4.7× over
Bromoform
Disinfection byproduct
1.51 ppb 0.5 — — — — — 3.0× over
Radium, combined (-226 and -228)*
Radiological
0.07 pCi/L 0.05 5.0 — — — — 1.4× over
Perchlorate
Disinfection byproduct
0.795 ppb 1.0 — — — — — Below guideline
Chlorate
Disinfection byproduct
61.3 ppb 210.0 — — — — — Below guideline
Aluminum*
Heavy metal
77.5 ppb 600.0 — 200 — 600 — Below guideline
1,4-Dioxane
Semi-volatile organic compound
0.0426 ppb 0.35 — — 50 1 — Below guideline
Molybdenum
Other
4.67 ppb 40.0 — — — — — Below guideline
Barium
Heavy metal
62.6 ppb 700.0 2000.0 — 1300 2000 — Below guideline
Vanadium
Other
1.64 ppb 21.0 — — — — — Below guideline
Perfluoropentane sulfonic acid (PFPeS)
PFAS
0.076 ppt 1.0 — — — — — Below guideline
Manganese
Heavy metal
0.274 ppb 100.0 — 50 80 — — Below guideline
Perfluorohexanoic Acid (PFHxA)
PFAS
1.57 ppt 1000.0 — — — — — Below guideline
Perfluorobutanoic Acid (PFBA)
PFAS
1.24 ppt 1000.0 — — — — — Below guideline
Perfluoropentanoic Acid (PFPeA)
PFAS
0.776 ppt 1000.0 — — — — — Below guideline
Perfluoroheptanoic acid (PFHPA)
PFAS
0.629 ppt 1000.0 — — — — — Below guideline
Perfluorobutane sulfonate (PFBS)
PFAS
1.16 ppt 2000.0 — — — — — Below guideline
Strontium
Radiological
0.661 ppb 1500.0 — — — — — Below guideline
1,1-Dichloroethylene
Volatile organic compound
0.00811 ppb — 7.0 — — — — Below guideline
Bromide
Other
42.3 ppb — — — — — — Below guideline
Fluoride
Inorganic
0.341 ppm — 4.0 1.5 1.5 — — Below guideline
Germanium
Other
0.0248 ppb — — — — — — Below guideline
Lithium
Other
22.2 ppb — — — — — — Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines, California OEHHA PHGs, EWG Tap Water Database.

Treatment plant contact info

For service issues, water quality concerns, or to request a Consumer Confidence Report from CITY OF SANTA ANA.

Treatment Plant

FacilityGARTHE (BRISTOL) RESERVOIR - INACTIVE

ZIP codes served

Santa Ana's public water systems serve the following ZIP codes: