Tap water quality in TORRANCE, California

Served by TORRANCE-CITY, WATER DEPT.. 106,183 residents.

Average score 64/100
Utilities 1
Population 106,183
D
64/100
Below Average
ⓘ How did we get this rating?
Quick answer

Tap water in TORRANCE, California receives a grade of D (64/100) from TapWaterSafety.org. It's served by TORRANCE-CITY, WATER DEPT.. The most significant water quality concerns are: Haloacetic acids (HAA5) significantly above health guideline; Total trihalomethanes (TTHMs) significantly above health guideline; Haloacetic acids (HAA9) significantly above health guideline; Arsenic detected. Data sources: EPA SDWIS, EPA ECHO, EWG Tap Water Database.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?

What's in TORRANCE's tap water

Top water quality concerns identified by the EPA and Environmental Working Group across the utility serving TORRANCE.

Haloacetic acids (HAA5) significantly above health guideline

Moderate concern

Haloacetic acids (HAA5) detected at 36.2 ppb, 362x above the EWG health guideline of 0.1 ppb.

Total trihalomethanes (TTHMs) significantly above health guideline

Moderate concern

Total trihalomethanes (TTHMs) detected at 31.8 ppb, 212x above the EWG health guideline of 0.15 ppb.

Haloacetic acids (HAA9) significantly above health guideline

Moderate concern

Haloacetic acids (HAA9) detected at 12.6 ppb, 209x above the EWG health guideline of 0.06 ppb.

Arsenic detected

Moderate concern

Arsenic detected at 0.6 ppb.

Recommended filters for TORRANCE

Filters matched to the specific contaminants in TORRANCE's water supply.

Reverse Osmosis

$249-$750

Arsenic is most effectively removed by reverse osmosis. Some specialized adsorptive filters also work.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Waterdrop G3P800 Tankless RO
$600-$750 NSF 58, 372
View on retailer →
Waterdrop N1 Countertop RO
$249-$329 NSF 58, 372
View on retailer →

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

All contaminants detected in TORRANCE's tap water

Every contaminant identified, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal. Why we show multiple standards →

Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Haloacetic acids (HAA5)
Disinfection byproduct
36.2 ppb 0.1 60.0 60 362× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
31.8 ppb 0.15 80.0 100 212× over
Haloacetic acids (HAA9)
Disinfection byproduct
12.6 ppb 0.06 209× over
Arsenic
Heavy metal
0.6 ppb 0.004 10.0 10 10 0.004 150× over
Bromodichloromethane
Disinfection byproduct
6.21 ppb 0.06 103× over
Dibromoacetic acid
Disinfection byproduct
3.04 ppb 0.03 101× over
Dibromochloromethane
Disinfection byproduct
9.74 ppb 0.1 97× over
Bromoform
Disinfection byproduct
10.8 ppb 0.5 22× over
Trichloroacetic acid
Disinfection byproduct
1.9 ppb 0.1 19× over
Dichloroacetic acid
Disinfection byproduct
3.32 ppb 0.2 17× over
Chloroform
Disinfection byproduct
5.0 ppb 0.4 13× over
Uranium*
Radiological
1.33 pCi/L 0.43 20.0 30 30 0.43 3.1× over
Radium, combined (-226 and -228)
Radiological
0.12 pCi/L 0.05 5.0 2.3× over
Nitrate*
Inorganic
0.281 ppm 0.14 10.0 11.3 11.3 10 2.0× over
Nitrate and nitrite*
Inorganic
0.287 ppm 0.14 10.0 11.3 11.3 10 2.0× over
Chromium (hexavalent)
Heavy metal
0.0181 ppb 0.02 Below guideline
Chlorate
Disinfection byproduct
180.3 ppb 210.0 Below guideline
Barium
Heavy metal
106.4 ppb 700.0 2000.0 1300 2000 Below guideline
MTBE
Volatile organic compound
1.96 ppb 13.0 Below guideline
Manganese
Heavy metal
8.06 ppb 100.0 50 80 Below guideline
Aluminum
Heavy metal
42.0 ppb 600.0 200 600 Below guideline
Vanadium
Other
1.15 ppb 21.0 Below guideline
Molybdenum
Other
1.91 ppb 40.0 Below guideline
Monobromoacetic acid
Disinfection byproduct
0.0284 ppb 25.0 Below guideline
Strontium
Radiological
0.777 ppb 1500.0 Below guideline
Chromium (total)
Heavy metal
0.366 ppb 100.0 Below guideline
Fluoride
Inorganic
0.273 ppm 4.0 1.5 1.5 Below guideline
Lithium
Other
13.1 ppb Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines, California OEHHA PHGs, EWG Tap Water Database.

Treatment plant contact info

For service issues, water quality concerns, or to request a Consumer Confidence Report from TORRANCE-CITY, WATER DEPT..

Treatment Plant

FacilityWELL 06 TREATMENT PLANT EFFLUENT

ZIP codes served

TORRANCE's public water systems serve the following ZIP codes: