Tap water in PUEBLO, Colorado receives a grade of B (81/100) from TapWaterSafety.org. It's served by PUEBLO BOARD OF WW. The most significant water quality concerns are: Haloacetic acids (HAA9) significantly above health guideline; Radium, combined (-226 and -228) significantly above health guideline. Data sources: EPA SDWIS, EPA ECHO, EWG Tap Water Database.
What's in PUEBLO's tap water
Top water quality concerns identified by the EPA and Environmental Working Group across the utility serving PUEBLO.
Haloacetic acids (HAA9) significantly above health guideline
Moderate concernHaloacetic acids (HAA9) detected at 16.1 ppb, 268x above the EWG health guideline of 0.06 ppb.
Radium, combined (-226 and -228) significantly above health guideline
Moderate concernRadium, combined (-226 and -228) detected at 1.45 pCi/L, 29x above the EWG health guideline of 0.05 pCi/L.
Recommended filters for PUEBLO
Filters matched to the specific contaminants in PUEBLO's water supply.
Carbon block (NSF/ANSI 42 + 53)
$40-$750Activated carbon is highly effective for disinfection byproducts like TTHM and HAA5.
Reverse Osmosis or water softener
$249-$750RO removes radium effectively; ion-exchange water softeners also reduce radium concentration.
Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.
All contaminants detected in PUEBLO's tap water
Every contaminant identified, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal. Why we show multiple standards →
| Contaminant | Detected | EWG US health-based |
EPA US legal |
EU DWD Europe |
WHO global |
CA PHG strictest US |
Tested sample year |
Status |
|---|---|---|---|---|---|---|---|---|
| Haloacetic acids (HAA9) Disinfection byproduct |
16.1 ppb | 0.06 | — | — | — | — | — | 268× over |
| Radium, combined (-226 and -228) Radiological |
1.45 pCi/L | 0.05 | 5.0 | — | — | — | — | 29× over |
| Uranium Radiological |
1.47 pCi/L | 0.43 | 20.0 | 30 | 30 | 0.43 | — | 3.4× over |
| Chromium (hexavalent) Heavy metal |
0.035 ppb | 0.02 | — | — | — | — | — | 1.8× over |
| Nitrate Inorganic |
0.13 ppm | 0.14 | 10.0 | 11.3 | 11.3 | 10 | — | Below guideline |
| Nitrate and nitrite Inorganic |
0.13 ppm | 0.14 | 10.0 | 11.3 | 11.3 | 10 | — | Below guideline |
| Selenium Heavy metal |
4.15 ppb | 30.0 | 50.0 | 20 | 40 | 30 | — | Below guideline |
| Molybdenum Other |
5.24 ppb | 40.0 | — | — | — | — | — | Below guideline |
| Barium Heavy metal |
46.9 ppb | 700.0 | 2000.0 | — | 1300 | 2000 | — | Below guideline |
| Vanadium Other |
0.713 ppb | 21.0 | — | — | — | — | — | Below guideline |
| Manganese Heavy metal |
2.01 ppb | 100.0 | — | 50 | 80 | — | — | Below guideline |
| Strontium Radiological |
0.486 ppb | 1500.0 | — | — | — | — | — | Below guideline |
| Fluoride Inorganic |
0.71 ppm | — | 4.0 | 1.5 | 1.5 | — | — | Below guideline |
| Lithium Other |
9.6 ppb | — | — | — | — | — | — | Below guideline |
All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.
Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines, California OEHHA PHGs, EWG Tap Water Database.
Treatment plant contact info
For service issues, water quality concerns, or to request a Consumer Confidence Report from PUEBLO BOARD OF WW.