Tap Water Quality Report
Tap water quality in MARGATE, Florida
Tap water in MARGATE, Florida receives a grade of F (56/100) from TapWaterSafety.org. It's served by CITY OF MARGATE. The most significant water quality concerns are: PFAS contamination; Perfluorohexane sulfonate (PFHXS) significantly above health guideline; Haloacetic acids (HAA9) significantly above health guideline; Haloacetic acids (HAA5) significantly above health guideline. Data sources: EPA SDWIS, EPA ECHO, EWG Tap Water Database.
What's in MARGATE's tap water
Top water quality concerns identified by the EPA and Environmental Working Group across the utility serving MARGATE.
PFAS contamination
Severe concernPerfluorooctane sulfonate (PFOS), Perfluorooctanoic acid (PFOA) detected. PFAS are persistent chemicals linked to cancer and immune effects with no known safe exposure threshold.
Perfluorohexane sulfonate (PFHXS) significantly above health guideline
Moderate concernPerfluorohexane sulfonate (PFHXS) detected at 4.7 ppt, 4700x above the EWG health guideline of 0.001 ppt.
Haloacetic acids (HAA9) significantly above health guideline
Moderate concernHaloacetic acids (HAA9) detected at 13.6 ppb, 226x above the EWG health guideline of 0.06 ppb.
Haloacetic acids (HAA5) significantly above health guideline
Moderate concernHaloacetic acids (HAA5) detected at 16.1 ppb, 161x above the EWG health guideline of 0.1 ppb.
Recommended filters for MARGATE
Filters matched to the specific contaminants in MARGATE's water supply.
Reverse Osmosis or NSF P473 certified carbon
$80-$750Activated carbon and RO are the only technologies proven to remove PFAS at certified levels.
Carbon block (NSF/ANSI 42 + 53)
$40-$750Activated carbon is highly effective for disinfection byproducts like TTHM and HAA5.
Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.
All contaminants detected in MARGATE's tap water
Every contaminant identified, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal. Why we show multiple standards →
| Contaminant | Detected | EWG US health-based |
EPA US legal |
EU DWD Europe |
WHO global |
CA PHG strictest US |
Tested sample year |
Status |
|---|---|---|---|---|---|---|---|---|
| Perfluorooctane sulfonate (PFOS) PFAS |
22.2 ppt | 0.3 | 4.0 | 100 | 100 | 1 | — | EPA violation |
| Perfluorooctanoic acid (PFOA) PFAS |
5.4 ppt | 0.09 | 4.0 | 100 | 100 | 0.007 | — | EPA violation |
| Perfluorohexane sulfonate (PFHXS) PFAS |
4.7 ppt | 0.001 | 10.0 | — | — | — | — | 4700× over |
| Haloacetic acids (HAA9) Disinfection byproduct |
13.6 ppb | 0.06 | — | — | — | — | — | 226× over |
| Haloacetic acids (HAA5) Disinfection byproduct |
16.1 ppb | 0.1 | 60.0 | 60 | — | — | — | 161× over |
| Total trihalomethanes (TTHMs) Disinfection byproduct |
13.9 ppb | 0.15 | 80.0 | 100 | — | — | — | 93× over |
| Radium, combined (-226 and -228) Radiological |
1.15 pCi/L | 0.05 | 5.0 | — | — | — | — | 23× over |
| Chromium (hexavalent) Heavy metal |
0.19 ppb | 0.02 | — | — | — | — | — | 9.5× over |
| Cadmium Heavy metal |
0.1 ppb | 0.04 | 5.0 | 5 | 3 | 0.04 | — | 2.5× over |
| Chlorate Disinfection byproduct |
355.3 ppb | 210.0 | — | — | — | — | — | 1.7× over |
| Aluminum Heavy metal |
50.6 ppb | 600.0 | — | 200 | — | 600 | — | Below guideline |
| Vanadium Other |
0.593 ppb | 21.0 | — | — | — | — | — | Below guideline |
| Molybdenum Other |
0.967 ppb | 40.0 | — | — | — | — | — | Below guideline |
| Barium Heavy metal |
6.0 ppb | 700.0 | 2000.0 | — | 1300 | 2000 | — | Below guideline |
| Perfluoropentanoic Acid (PFPeA) PFAS |
7.4 ppt | 1000.0 | — | — | — | — | — | Below guideline |
| Perfluorobutanoic Acid (PFBA) PFAS |
6.3 ppt | 1000.0 | — | — | — | — | — | Below guideline |
| Perfluorohexanoic Acid (PFHxA) PFAS |
5.1 ppt | 1000.0 | — | — | — | — | — | Below guideline |
| Perfluorobutane sulfonate (PFBS) PFAS |
4.8 ppt | 2000.0 | — | — | — | — | — | Below guideline |
| Manganese Heavy metal |
0.23 ppb | 100.0 | — | 50 | 80 | — | — | Below guideline |
| Strontium Radiological |
0.311 ppb | 1500.0 | — | — | — | — | — | Below guideline |
| Fluoride Inorganic |
0.591 ppm | — | 4.0 | 1.5 | 1.5 | — | — | Below guideline |
All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.
Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines, California OEHHA PHGs, EWG Tap Water Database.
Treatment plant contact info