Water Quality Report · Updated May 12, 2026
CATOOSA UTIL. DIST. AUTHORITY
CATOOSA UTIL. DIST. AUTHORITY delivers tap water graded C (67/100) by TapWaterSafety.org. The utility serves approximately 56,670 residents in RINGGOLD, Georgia using surface water (purchased). The most significant water quality concerns are: Haloacetic acids (HAA9) significantly above health guideline; Total trihalomethanes (TTHMs) significantly above health guideline; Haloacetic acids (HAA5) significantly above health guideline. For questions, the utility can be reached at 706-937-4121.
Is RINGGOLD tap water safe to drink?
CATOOSA UTIL. DIST. AUTHORITY delivers tap water that earns a grade of C (67/100) from TapWaterSafety.org — an average rating, with several contaminants above health guidelines but generally compliant with US legal limits.
The utility serves 56,670 residents in RINGGOLD, drawing from surface water (purchased).
Public testing data identifies 12 contaminants in this water above EWG's health-based guidelines, including: Haloacetic acids (HAA9), Total trihalomethanes (TTHMs), Haloacetic acids (HAA5), Trichloroacetic acid, Bromodichloromethane, Chloroform, Dichloroacetic acid, Dibromochloromethane, Radium, combined (-226 and -228)*, Chromium (hexavalent), Nitrate and nitrite, Nitrate*. For most residents, a properly certified home filter at the kitchen tap is the most cost-effective way to reduce exposure to whatever's in your water. See our filter recommendations below, matched specifically to this utility's contaminant profile.
Quick actions for RINGGOLD residents
Top concerns in this water
Based on the most recent EPA and EWG data, these are the most significant water quality issues for CATOOSA UTIL. DIST. AUTHORITY.
Haloacetic acids (HAA9) significantly above health guideline
Moderate concernHaloacetic acids (HAA9) detected at 13.6 ppb, 227x above the EWG health guideline of 0.06 ppb.
Total trihalomethanes (TTHMs) significantly above health guideline
Moderate concernTotal trihalomethanes (TTHMs) detected at 25.8 ppb, 172x above the EWG health guideline of 0.15 ppb.
Haloacetic acids (HAA5) significantly above health guideline
Moderate concernHaloacetic acids (HAA5) detected at 12.5 ppb, 125x above the EWG health guideline of 0.1 ppb.
Contact CATOOSA UTIL. DIST. AUTHORITY
Reach the utility directly for service issues, water quality concerns, or to request your Consumer Confidence Report.
General Contact
Treatment Plant
Recommended water filters for RINGGOLD
Filters matched to the specific contaminants in this water supply.
Carbon block (NSF/ANSI 42 + 53)
$40-$750Activated carbon is highly effective for disinfection byproducts like TTHM and HAA5.
Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.
Score breakdown
This utility's overall score of 67/100 breaks down across five weighted components. Read the full methodology →
Contaminants detected — international standards comparison
Every contaminant detected, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal (the strictest US benchmark). Why we show multiple standards →
| Contaminant | Detected | EWG US health-based |
EPA US legal |
EU DWD Europe |
WHO global |
CA PHG strictest US |
Tested sample year |
Status |
|---|---|---|---|---|---|---|---|---|
| Haloacetic acids (HAA9) Disinfection byproduct |
13.6 ppb | 0.06 | — | — | — | — | — | 227× over |
| Total trihalomethanes (TTHMs) Disinfection byproduct |
25.8 ppb | 0.15 | 80.0 | 100 | — | — | — | 172× over |
| Haloacetic acids (HAA5) Disinfection byproduct |
12.5 ppb | 0.1 | 60.0 | 60 | — | — | — | 125× over |
| Trichloroacetic acid Disinfection byproduct |
6.35 ppb | 0.1 | — | — | — | — | — | 64× over |
| Bromodichloromethane Disinfection byproduct |
3.42 ppb | 0.06 | — | — | — | — | — | 57× over |
| Chloroform Disinfection byproduct |
19.6 ppb | 0.4 | — | — | — | — | — | 49× over |
| Dichloroacetic acid Disinfection byproduct |
6.14 ppb | 0.2 | — | — | — | — | — | 31× over |
| Dibromochloromethane Disinfection byproduct |
2.14 ppb | 0.1 | — | — | — | — | — | 21× over |
| Radium, combined (-226 and -228)* Radiological |
0.61 pCi/L | 0.05 | 5.0 | — | — | — | — | 12× over |
| Chromium (hexavalent) Heavy metal |
0.201 ppb | 0.02 | — | — | — | — | — | 10× over |
| Nitrate and nitrite Inorganic |
0.85 ppm | 0.14 | 10.0 | 11.3 | 11.3 | 10 | — | 6.1× over |
| Nitrate* Inorganic |
0.357 ppm | 0.14 | 10.0 | 11.3 | 11.3 | 10 | — | 2.5× over |
| 1,4-Dioxane* Semi-volatile organic compound |
0.1 ppb | 0.35 | — | — | 50 | 1 | — | Below guideline |
| Barium Heavy metal |
68.7 ppb | 700.0 | 2000.0 | — | 1300 | 2000 | — | Below guideline |
| Aluminum* Heavy metal |
26.0 ppb | 600.0 | — | 200 | — | 600 | — | Below guideline |
| Vanadium Other |
0.422 ppb | 21.0 | — | — | — | — | — | Below guideline |
| Chlorate Disinfection byproduct |
2.61 ppb | 210.0 | — | — | — | — | — | Below guideline |
| Perfluorobutanoic Acid (PFBA) PFAS |
6.36 ppt | 1000.0 | — | — | — | — | — | Below guideline |
| Manganese Heavy metal |
0.579 ppb | 100.0 | — | 50 | 80 | — | — | Below guideline |
| Perfluorobutane sulfonate (PFBS) PFAS |
7.52 ppt | 2000.0 | — | — | — | — | — | Below guideline |
| Strontium Radiological |
0.0226 ppb | 1500.0 | — | — | — | — | — | Below guideline |
| Fluoride Inorganic |
0.693 ppm | — | 4.0 | 1.5 | 1.5 | — | — | Below guideline |
All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.
Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines (4th ed.), California OEHHA PHGs, EWG Tap Water Database.
CATOOSA UTIL. DIST. AUTHORITY service area
This water system serves 1 community in Catoosa County, Georgia. Click any city for its dedicated tap water quality page.
Find the right filter for RINGGOLD water
Browse filter categories by water-quality concern. Each option below is NSF-certified for the matched contaminant type.