Water Quality Report · Updated May 12, 2026

CATOOSA UTIL. DIST. AUTHORITY

Serving 56,670 residents in RINGGOLD, Georgia .

National rank 68th percentile
Georgia rank 65th percentile
Data confidence Medium
Quick answer

CATOOSA UTIL. DIST. AUTHORITY delivers tap water graded C (67/100) by TapWaterSafety.org. The utility serves approximately 56,670 residents in RINGGOLD, Georgia using surface water (purchased). The most significant water quality concerns are: Haloacetic acids (HAA9) significantly above health guideline; Total trihalomethanes (TTHMs) significantly above health guideline; Haloacetic acids (HAA5) significantly above health guideline. For questions, the utility can be reached at 706-937-4121.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?
56,670
People served
1
City served
22
Contaminants detected
12
Above health guidelines
0
EPA violations (5 yr)

Is RINGGOLD tap water safe to drink?

CATOOSA UTIL. DIST. AUTHORITY delivers tap water that earns a grade of C (67/100) from TapWaterSafety.org — an average rating, with several contaminants above health guidelines but generally compliant with US legal limits.

The utility serves 56,670 residents in RINGGOLD, drawing from surface water (purchased).

Public testing data identifies 12 contaminants in this water above EWG's health-based guidelines, including: Haloacetic acids (HAA9), Total trihalomethanes (TTHMs), Haloacetic acids (HAA5), Trichloroacetic acid, Bromodichloromethane, Chloroform, Dichloroacetic acid, Dibromochloromethane, Radium, combined (-226 and -228)*, Chromium (hexavalent), Nitrate and nitrite, Nitrate*. For most residents, a properly certified home filter at the kitchen tap is the most cost-effective way to reduce exposure to whatever's in your water. See our filter recommendations below, matched specifically to this utility's contaminant profile.

Top concerns in this water

Based on the most recent EPA and EWG data, these are the most significant water quality issues for CATOOSA UTIL. DIST. AUTHORITY.

Haloacetic acids (HAA9) significantly above health guideline

Moderate concern

Haloacetic acids (HAA9) detected at 13.6 ppb, 227x above the EWG health guideline of 0.06 ppb.

Total trihalomethanes (TTHMs) significantly above health guideline

Moderate concern

Total trihalomethanes (TTHMs) detected at 25.8 ppb, 172x above the EWG health guideline of 0.15 ppb.

Haloacetic acids (HAA5) significantly above health guideline

Moderate concern

Haloacetic acids (HAA5) detected at 12.5 ppb, 125x above the EWG health guideline of 0.1 ppb.

Contact CATOOSA UTIL. DIST. AUTHORITY

Reach the utility directly for service issues, water quality concerns, or to request your Consumer Confidence Report.

Recommended water filters for RINGGOLD

Filters matched to the specific contaminants in this water supply.

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

Score breakdown

This utility's overall score of 67/100 breaks down across five weighted components. Read the full methodology →

Health Guideline Performance
10 / 40
Legal Compliance
20 / 20
High-Risk Contaminants
20 / 20
Compliance History
10 / 10
Source Water Vulnerability
7 / 10

Contaminants detected — international standards comparison

Every contaminant detected, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal (the strictest US benchmark). Why we show multiple standards →

Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Haloacetic acids (HAA9)
Disinfection byproduct
13.6 ppb 0.06 227× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
25.8 ppb 0.15 80.0 100 172× over
Haloacetic acids (HAA5)
Disinfection byproduct
12.5 ppb 0.1 60.0 60 125× over
Trichloroacetic acid
Disinfection byproduct
6.35 ppb 0.1 64× over
Bromodichloromethane
Disinfection byproduct
3.42 ppb 0.06 57× over
Chloroform
Disinfection byproduct
19.6 ppb 0.4 49× over
Dichloroacetic acid
Disinfection byproduct
6.14 ppb 0.2 31× over
Dibromochloromethane
Disinfection byproduct
2.14 ppb 0.1 21× over
Radium, combined (-226 and -228)*
Radiological
0.61 pCi/L 0.05 5.0 12× over
Chromium (hexavalent)
Heavy metal
0.201 ppb 0.02 10× over
Nitrate and nitrite
Inorganic
0.85 ppm 0.14 10.0 11.3 11.3 10 6.1× over
Nitrate*
Inorganic
0.357 ppm 0.14 10.0 11.3 11.3 10 2.5× over
1,4-Dioxane*
Semi-volatile organic compound
0.1 ppb 0.35 50 1 Below guideline
Barium
Heavy metal
68.7 ppb 700.0 2000.0 1300 2000 Below guideline
Aluminum*
Heavy metal
26.0 ppb 600.0 200 600 Below guideline
Vanadium
Other
0.422 ppb 21.0 Below guideline
Chlorate
Disinfection byproduct
2.61 ppb 210.0 Below guideline
Perfluorobutanoic Acid (PFBA)
PFAS
6.36 ppt 1000.0 Below guideline
Manganese
Heavy metal
0.579 ppb 100.0 50 80 Below guideline
Perfluorobutane sulfonate (PFBS)
PFAS
7.52 ppt 2000.0 Below guideline
Strontium
Radiological
0.0226 ppb 1500.0 Below guideline
Fluoride
Inorganic
0.693 ppm 4.0 1.5 1.5 Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines (4th ed.), California OEHHA PHGs, EWG Tap Water Database.

CATOOSA UTIL. DIST. AUTHORITY service area

This water system serves 1 community in Catoosa County, Georgia. Click any city for its dedicated tap water quality page.

About this water system

Public Water System ID
GA0470000
Owner type
Local government
Source water
Surface water (purchased)
Service connections
21,796
Service area
RINGGOLD, Catoosa County, Georgia