Water Quality Report · Updated May 12, 2026

MARIETTA BOARD OF LIGHTS AND WATER

Serving 60,100 residents in MARIETTA, Georgia .

National rank 56th percentile
Georgia rank 32th percentile
Data confidence Medium
Quick answer

MARIETTA BOARD OF LIGHTS AND WATER delivers tap water graded C (65/100) by TapWaterSafety.org. The utility serves approximately 60,100 residents in MARIETTA, Georgia using surface water (purchased). The most significant water quality concerns are: Haloacetic acids (HAA9) significantly above health guideline; Total trihalomethanes (TTHMs) significantly above health guideline; Haloacetic acids (HAA5) significantly above health guideline. For questions, the utility can be reached at 770-794-5502.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?
60,100
People served
1
City served
15
Contaminants detected
11
Above health guidelines
0
EPA violations (5 yr)

Is MARIETTA tap water safe to drink?

MARIETTA BOARD OF LIGHTS AND WATER delivers tap water that earns a grade of C (65/100) from TapWaterSafety.org — an average rating, with several contaminants above health guidelines but generally compliant with US legal limits.

The utility serves 60,100 residents in MARIETTA, drawing from surface water (purchased).

Public testing data identifies 11 contaminants in this water above EWG's health-based guidelines, including: Haloacetic acids (HAA9), Total trihalomethanes (TTHMs), Haloacetic acids (HAA5), Bromodichloromethane, Chloroform, Trichloroacetic acid, Dichloroacetic acid, Dibromochloromethane, Chromium (hexavalent), Dibromoacetic acid, Chlorate. For most residents, a properly certified home filter at the kitchen tap is the most cost-effective way to reduce exposure to whatever's in your water. See our filter recommendations below, matched specifically to this utility's contaminant profile.

Top concerns in this water

Based on the most recent EPA and EWG data, these are the most significant water quality issues for MARIETTA BOARD OF LIGHTS AND WATER.

Haloacetic acids (HAA9) significantly above health guideline

Moderate concern

Haloacetic acids (HAA9) detected at 33.3 ppb, 555x above the EWG health guideline of 0.06 ppb.

Total trihalomethanes (TTHMs) significantly above health guideline

Moderate concern

Total trihalomethanes (TTHMs) detected at 51.9 ppb, 346x above the EWG health guideline of 0.15 ppb.

Haloacetic acids (HAA5) significantly above health guideline

Moderate concern

Haloacetic acids (HAA5) detected at 23.3 ppb, 233x above the EWG health guideline of 0.1 ppb.

Contact MARIETTA BOARD OF LIGHTS AND WATER

Reach the utility directly for service issues, water quality concerns, or to request your Consumer Confidence Report.

Recommended water filters for MARIETTA

Filters matched to the specific contaminants in this water supply.

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

Score breakdown

This utility's overall score of 65/100 breaks down across five weighted components. Read the full methodology →

Health Guideline Performance
10 / 40
Legal Compliance
20 / 20
High-Risk Contaminants
18 / 20
Compliance History
10 / 10
Source Water Vulnerability
7 / 10

Contaminants detected — international standards comparison

Every contaminant detected, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal (the strictest US benchmark). Why we show multiple standards →

Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Haloacetic acids (HAA9)
Disinfection byproduct
33.3 ppb 0.06 555× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
51.9 ppb 0.15 80.0 100 346× over
Haloacetic acids (HAA5)
Disinfection byproduct
23.3 ppb 0.1 60.0 60 233× over
Bromodichloromethane
Disinfection byproduct
7.24 ppb 0.06 121× over
Chloroform
Disinfection byproduct
41.1 ppb 0.4 103× over
Trichloroacetic acid
Disinfection byproduct
9.88 ppb 0.1 99× over
Dichloroacetic acid
Disinfection byproduct
13.3 ppb 0.2 66× over
Dibromochloromethane
Disinfection byproduct
3.58 ppb 0.1 36× over
Chromium (hexavalent)
Heavy metal
0.0686 ppb 0.02 3.4× over
Dibromoacetic acid
Disinfection byproduct
0.0575 ppb 0.03 1.9× over
Chlorate
Disinfection byproduct
283.5 ppb 210.0 1.4× over
Manganese
Heavy metal
1.28 ppb 100.0 50 80 Below guideline
Monobromoacetic acid
Disinfection byproduct
0.0655 ppb 25.0 Below guideline
Monochloroacetic acid
Disinfection byproduct
0.0138 ppb 53.0 Below guideline
Strontium
Radiological
0.0344 ppb 1500.0 Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines (4th ed.), California OEHHA PHGs, EWG Tap Water Database.

MARIETTA BOARD OF LIGHTS AND WATER service area

This water system serves 1 community in Cobb County, Georgia. Click any city for its dedicated tap water quality page.

About this water system

Public Water System ID
GA0670005
Owner type
Local government
Source water
Surface water (purchased)
Service connections
18,100
Service area
MARIETTA, Cobb County, Georgia