Water Quality Report · Updated May 12, 2026

BATON ROUGE WATER COMPANY

Serving 596,844 residents in BATON ROUGE, Louisiana .

National rank 95th percentile
Louisiana rank 100th percentile
Data confidence Medium
Quick answer

BATON ROUGE WATER COMPANY delivers tap water graded B (79/100) by TapWaterSafety.org. The utility serves approximately 596,844 residents in BATON ROUGE, Louisiana using groundwater. The most significant water quality concerns are: Haloacetic acids (HAA9) significantly above health guideline; Haloacetic acids (HAA5) significantly above health guideline; Total trihalomethanes (TTHMs) significantly above health guideline; Arsenic detected.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?
596,844
People served
1
City served
27
Contaminants detected
9
Above health guidelines
0
EPA violations (5 yr)

Is BATON ROUGE tap water safe to drink?

BATON ROUGE WATER COMPANY delivers tap water that earns a grade of B (79/100) from TapWaterSafety.org — a good rating, with only minor concerns relative to health-based guidelines.

The utility serves 596,844 residents in BATON ROUGE, drawing from groundwater.

Public testing data identifies 9 contaminants in this water above EWG's health-based guidelines, including: Haloacetic acids (HAA9), Haloacetic acids (HAA5), Total trihalomethanes (TTHMs), Dichloroacetic acid, Arsenic, Chloroform, Trichloroacetic acid, Dibromoacetic acid, Radium, combined (-226 and -228). For most residents, a properly certified home filter at the kitchen tap is the most cost-effective way to reduce exposure to whatever's in your water. See our filter recommendations below, matched specifically to this utility's contaminant profile.

Quick actions for BATON ROUGE residents

Top concerns in this water

Based on the most recent EPA and EWG data, these are the most significant water quality issues for BATON ROUGE WATER COMPANY.

Haloacetic acids (HAA9) significantly above health guideline

Moderate concern

Haloacetic acids (HAA9) detected at 1.48 ppb, 25x above the EWG health guideline of 0.06 ppb.

Haloacetic acids (HAA5) significantly above health guideline

Moderate concern

Haloacetic acids (HAA5) detected at 1.82 ppb, 18x above the EWG health guideline of 0.1 ppb.

Total trihalomethanes (TTHMs) significantly above health guideline

Moderate concern

Total trihalomethanes (TTHMs) detected at 1.9 ppb, 13x above the EWG health guideline of 0.15 ppb.

Arsenic detected

Moderate concern

Arsenic detected at 0.0198 ppb.

Contact BATON ROUGE WATER COMPANY

Reach the utility directly for service issues, water quality concerns, or to request your Consumer Confidence Report.

Recommended water filters for BATON ROUGE

Filters matched to the specific contaminants in this water supply.

Reverse Osmosis

$249-$750

Arsenic is most effectively removed by reverse osmosis. Some specialized adsorptive filters also work.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Waterdrop G3P800 Tankless RO
$600-$750 NSF 58, 372
View on retailer →
Waterdrop N1 Countertop RO
$249-$329 NSF 58, 372
View on retailer →

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

Score breakdown

This utility's overall score of 79/100 breaks down across five weighted components. Read the full methodology →

Health Guideline Performance
21 / 40
Legal Compliance
20 / 20
High-Risk Contaminants
20 / 20
Compliance History
10 / 10
Source Water Vulnerability
8 / 10

Contaminants detected — international standards comparison

Every contaminant detected, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal (the strictest US benchmark). Why we show multiple standards →

Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Haloacetic acids (HAA9)
Disinfection byproduct
1.48 ppb 0.06 25× over
Haloacetic acids (HAA5)
Disinfection byproduct
1.82 ppb 0.1 60.0 60 18× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
1.9 ppb 0.15 80.0 100 13× over
Dichloroacetic acid
Disinfection byproduct
1.3 ppb 0.2 6.5× over
Arsenic
Heavy metal
0.0198 ppb 0.004 10.0 10 10 0.004 5.0× over
Chloroform
Disinfection byproduct
1.86 ppb 0.4 4.6× over
Trichloroacetic acid
Disinfection byproduct
0.347 ppb 0.1 3.5× over
Dibromoacetic acid
Disinfection byproduct
0.095 ppb 0.03 3.2× over
Radium, combined (-226 and -228)
Radiological
0.15 pCi/L 0.05 5.0 3.1× over
Bromodichloromethane
Disinfection byproduct
0.0473 ppb 0.06 Below guideline
Nitrate and nitrite
Inorganic
0.0583 ppm 0.14 10.0 11.3 11.3 10 Below guideline
Manganese
Heavy metal
20.3 ppb 100.0 50 80 Below guideline
Antimony
Heavy metal
0.0877 ppb 1.0 6.0 10 20 1 Below guideline
Chromium (hexavalent)
Heavy metal
0.00156 ppb 0.02 Below guideline
Aluminum
Heavy metal
10.8 ppb 600.0 200 600 Below guideline
Molybdenum
Other
0.339 ppb 40.0 Below guideline
Heptachlor epoxide
Other
3.8e-05 ppb 0.006 0.2 Below guideline
Barium
Heavy metal
2.55 ppb 700.0 2000.0 1300 2000 Below guideline
Monobromoacetic acid
Disinfection byproduct
0.0833 ppb 25.0 Below guideline
Vanadium
Other
0.0322 ppb 21.0 Below guideline
Cobalt
Other
0.0245 ppb 70.0 Below guideline
Strontium
Radiological
0.0155 ppb 1500.0 Below guideline
1-Butanol
Other
0.0561 ppb Below guideline
Fluoride
Inorganic
0.33 ppm 4.0 1.5 1.5 Below guideline
Germanium
Other
0.351 ppb Below guideline
Lithium
Other
13.6 ppb Below guideline
Silver
Other
0.396 ppb Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines (4th ed.), California OEHHA PHGs, EWG Tap Water Database.

BATON ROUGE WATER COMPANY service area

This water system serves 1 community in East Baton Rouge Parish County, Louisiana. Click any city for its dedicated tap water quality page.

About this water system

Public Water System ID
LA1033005
Owner type
Private
Source water
Groundwater
Service connections
198,948
Service area
BATON ROUGE, East Baton Rouge Parish County, Louisiana