Tap Water Quality Report

Tap water quality in MOONACHIE BORO-0237, New Jersey

Served by VEOLIA WATER NEW JERSEY HACKENSACK. 792,713 residents.

Average score 50/100
Utilities 1
Population 792,713
Quick answer

Tap water in MOONACHIE BORO-0237, New Jersey receives a grade of F (50/100) from TapWaterSafety.org. It's served by VEOLIA WATER NEW JERSEY HACKENSACK. The most significant water quality concerns are: PFAS contamination; Perfluorohexane sulfonate (PFHXS) significantly above health guideline; Haloacetic acids (HAA9) significantly above health guideline; Total trihalomethanes (TTHMs) significantly above health guideline; Arsenic detected. Data sources: EPA SDWIS, EPA ECHO, EWG Tap Water Database.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?

What's in MOONACHIE BORO-0237's tap water

Top water quality concerns identified by the EPA and Environmental Working Group across the utility serving MOONACHIE BORO-0237.

PFAS contamination

Severe concern

Perfluorononanoic acid (PFNA), Perfluorooctane sulfonate (PFOS) detected. PFAS are persistent chemicals linked to cancer and immune effects with no known safe exposure threshold.

Perfluorohexane sulfonate (PFHXS) significantly above health guideline

Moderate concern

Perfluorohexane sulfonate (PFHXS) detected at 2.68 ppt, 2675x above the EWG health guideline of 0.001 ppt.

Haloacetic acids (HAA9) significantly above health guideline

Moderate concern

Haloacetic acids (HAA9) detected at 23.6 ppb, 393x above the EWG health guideline of 0.06 ppb.

Total trihalomethanes (TTHMs) significantly above health guideline

Moderate concern

Total trihalomethanes (TTHMs) detected at 34.6 ppb, 231x above the EWG health guideline of 0.15 ppb.

Arsenic detected

Moderate concern

Arsenic detected at 0.236 ppb.

Recommended filters for MOONACHIE BORO-0237

Filters matched to the specific contaminants in MOONACHIE BORO-0237's water supply.

Reverse Osmosis or NSF P473 certified carbon

$80-$750

Activated carbon and RO are the only technologies proven to remove PFAS at certified levels.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Waterdrop G3P800 Tankless RO
$600-$750 NSF 58, 372
View on retailer →
Waterdrop N1 Countertop RO
$249-$329 NSF 58, 372
View on retailer →
Clearly Filtered Pitcher Filter
$80-$95 NSF 42, 53, 401, P473
Editorial pick · affiliate link coming soon

Reverse Osmosis

$249-$750

Arsenic is most effectively removed by reverse osmosis. Some specialized adsorptive filters also work.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Waterdrop G3P800 Tankless RO
$600-$750 NSF 58, 372
View on retailer →
Waterdrop N1 Countertop RO
$249-$329 NSF 58, 372
View on retailer →

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

All contaminants detected in MOONACHIE BORO-0237's tap water

Every contaminant identified, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal. Why we show multiple standards →

Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Perfluorooctanoic acid (PFOA)
PFAS
10.9 ppt 0.09 4.0 100 100 0.007 EPA violation
Perfluorooctane sulfonate (PFOS)
PFAS
6.21 ppt 0.3 4.0 100 100 1 EPA violation
Perfluorohexane sulfonate (PFHXS)
PFAS
2.68 ppt 0.001 10.0 2675× over
Haloacetic acids (HAA9)
Disinfection byproduct
23.6 ppb 0.06 393× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
34.6 ppb 0.15 80.0 100 231× over
Haloacetic acids (HAA5)
Disinfection byproduct
17.9 ppb 0.1 60.0 60 179× over
Bromodichloromethane
Disinfection byproduct
9.36 ppb 0.06 156× over
Perfluorononanoic acid (PFNA)
PFAS
0.482 ppt 0.006 10.0 80× over
Arsenic
Heavy metal
0.236 ppb 0.004 10.0 10 10 0.004 59× over
Dichloroacetic acid
Disinfection byproduct
10.3 ppb 0.2 51× over
Trichloroacetic acid
Disinfection byproduct
5.15 ppb 0.1 51× over
Chloroform
Disinfection byproduct
20.1 ppb 0.4 50× over
Dibromochloromethane
Disinfection byproduct
4.76 ppb 0.1 48× over
Dibromoacetic acid
Disinfection byproduct
1.32 ppb 0.03 44× over
Bromate
Disinfection byproduct
1.41 ppb 0.1 10.0 10 10 0.1 14× over
Chromium (hexavalent)
Heavy metal
0.148 ppb 0.02 7.4× over
Perfluoroundecanoic acid (PFUnA)
PFAS
0.015 ppt 0.006 2.5× over
Nitrate
Inorganic
0.331 ppm 0.14 10.0 11.3 11.3 10 2.4× over
Nitrate and nitrite
Inorganic
0.332 ppm 0.14 10.0 11.3 11.3 10 2.4× over
Chlorate
Disinfection byproduct
175.8 ppb 210.0 Below guideline
Bromoform
Disinfection byproduct
0.362 ppb 0.5 Below guideline
Perfluorododecanoic acid (PFDoA)
PFAS
0.015 ppt 0.06 Below guideline
Barium
Heavy metal
68.5 ppb 700.0 2000.0 1300 2000 Below guideline
Monobromoacetic acid
Disinfection byproduct
1.21 ppb 25.0 Below guideline
1,4-Dioxane
Semi-volatile organic compound
0.00817 ppb 0.35 50 1 Below guideline
Manganese
Heavy metal
1.33 ppb 100.0 50 80 Below guideline
Vanadium
Other
0.213 ppb 21.0 Below guideline
Toluene
Volatile organic compound
1.2 ppb 150.0 1000.0 Below guideline
Perfluorohexanoic Acid (PFHxA)
PFAS
5.77 ppt 1000.0 Below guideline
Perfluoroheptanoic acid (PFHPA)
PFAS
3.31 ppt 1000.0 Below guideline
Perfluoropentanoic Acid (PFPeA)
PFAS
2.31 ppt 1000.0 Below guideline
Perfluorobutane sulfonate (PFBS)
PFAS
1.9 ppt 2000.0 Below guideline
Strontium
Radiological
0.147 ppb 1500.0 Below guideline
Bromide
Other
50.7 ppb Below guideline
Chromium (total)
Heavy metal
1.68 ppb 100.0 Below guideline
Nitrite
Inorganic
0.000915 ppm 1.0 Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines, California OEHHA PHGs, EWG Tap Water Database.

Treatment plant contact info

For service issues, water quality concerns, or to request a Consumer Confidence Report from VEOLIA WATER NEW JERSEY HACKENSACK.

General Contact

Address200 LAKE SHORE DR, HAWORTH, NJ 07641
Main phone201-599-6020

Treatment Plant

FacilityBOGOTA #2

ZIP codes served

MOONACHIE BORO-0237's public water systems serve the following ZIP codes: