Tap Water Quality Report

Tap water quality in CONWAY, South Carolina

Served by GSW&SA (SC2620004). 252,840 residents.

Average score 55/100
Utilities 1
Population 252,840
Quick answer

Tap water in CONWAY, South Carolina receives a grade of F (55/100) from TapWaterSafety.org. It's served by GSW&SA (SC2620004). The most significant water quality concerns are: PFAS contamination; Haloacetic acids (HAA9) significantly above health guideline; Haloacetic acids (HAA5) significantly above health guideline; Total trihalomethanes (TTHMs) significantly above health guideline. Data sources: EPA SDWIS, EPA ECHO, EWG Tap Water Database.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?

What's in CONWAY's tap water

Top water quality concerns identified by the EPA and Environmental Working Group across the utility serving CONWAY.

PFAS contamination

Severe concern

Perfluorooctane sulfonate (PFOS), Perfluorooctanoic acid (PFOA) detected. PFAS are persistent chemicals linked to cancer and immune effects with no known safe exposure threshold.

Haloacetic acids (HAA9) significantly above health guideline

Moderate concern

Haloacetic acids (HAA9) detected at 36.2 ppb, 604x above the EWG health guideline of 0.06 ppb.

Haloacetic acids (HAA5) significantly above health guideline

Moderate concern

Haloacetic acids (HAA5) detected at 25.2 ppb, 252x above the EWG health guideline of 0.1 ppb.

Total trihalomethanes (TTHMs) significantly above health guideline

Moderate concern

Total trihalomethanes (TTHMs) detected at 30.8 ppb, 205x above the EWG health guideline of 0.15 ppb.

Recommended filters for CONWAY

Filters matched to the specific contaminants in CONWAY's water supply.

Reverse Osmosis or NSF P473 certified carbon

$80-$750

Activated carbon and RO are the only technologies proven to remove PFAS at certified levels.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401, P473
Editorial pick · affiliate link coming soon
Waterdrop G3P800 Tankless RO
$600-$750 NSF 58, 372
View on retailer →
Waterdrop N1 Countertop RO
$249-$329 NSF 58, 372
View on retailer →
Clearly Filtered Pitcher Filter
$80-$95 NSF 42, 53, 401, P473
Editorial pick · affiliate link coming soon

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

All contaminants detected in CONWAY's tap water

Every contaminant identified, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal. Why we show multiple standards →

🇪🇺
CONWAY's tap water would fail European Union drinking water standards. One or more detected contaminants exceed EU Drinking Water Directive 2020/2184 limits, even though they may be fully legal under US EPA rules. View the standards we compare against →
Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Haloacetic acids (HAA9)
Disinfection byproduct
36.2 ppb 0.06 604× over
Haloacetic acids (HAA5)
Disinfection byproduct
25.2 ppb 0.1 60.0 60 252× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
30.8 ppb 0.15 80.0 100 205× over
Bromodichloromethane
Disinfection byproduct
5.62 ppb 0.06 94× over
Trichloroacetic acid
Disinfection byproduct
8.71 ppb 0.1 87× over
Dichloroacetic acid
Disinfection byproduct
16.3 ppb 0.2 81× over
Chloroform
Disinfection byproduct
24.9 ppb 0.4 62× over
Perfluorooctanoic acid (PFOA)
PFAS
3.36 ppt 0.09 4.0 100 100 0.007 37× over
Perfluorooctane sulfonate (PFOS)
PFAS
3.48 ppt 0.3 4.0 100 100 1 12× over
Dibromochloromethane
Disinfection byproduct
0.282 ppb 0.1 2.8× over
Nitrate and nitrite
Inorganic
0.345 ppm 0.14 10.0 11.3 11.3 10 2.5× over
Chromium (hexavalent)
Heavy metal
0.0461 ppb 0.02 2.3× over
Nitrate
Inorganic
0.314 ppm 0.14 10.0 11.3 11.3 10 2.2× over
Atrazine
Pesticide/Herbicide
0.182 ppb 0.1 3.0 0.1 100 0.15 Fails EU
Chlorate
Disinfection byproduct
167.5 ppb 210.0 Below guideline
1,4-Dioxane
Semi-volatile organic compound
0.178 ppb 0.35 50 1 Below guideline
Dibromoacetic acid
Disinfection byproduct
0.0117 ppb 0.03 Below guideline
Manganese
Heavy metal
4.36 ppb 100.0 50 80 Below guideline
Vanadium
Other
0.305 ppb 21.0 Below guideline
Monochloroacetic acid
Disinfection byproduct
0.271 ppb 53.0 Below guideline
Molybdenum
Other
0.15 ppb 40.0 Below guideline
Perfluoropentanoic Acid (PFPeA)
PFAS
3.72 ppt 1000.0 Below guideline
Perfluorohexanoic Acid (PFHxA)
PFAS
2.19 ppt 1000.0 Below guideline
Monochlorobenzene (chlorobenzene)
Volatile organic compound
0.133 ppb 70.0 100.0 1 10 0.15 Below guideline
Perfluorobutanoic Acid (PFBA)
PFAS
1.63 ppt 1000.0 Below guideline
Perfluoroheptanoic acid (PFHPA)
PFAS
1.25 ppt 1000.0 Below guideline
Perfluorobutane sulfonate (PFBS)
PFAS
1.38 ppt 2000.0 Below guideline
Strontium
Radiological
0.0503 ppb 1500.0 Below guideline
Dicamba
Other
0.13 ppb Below guideline
Fluoride
Inorganic
1.21 ppm 4.0 1.5 1.5 Below guideline
Lithium
Other
5.99 ppb Below guideline
Metolachlor
Pesticide/Herbicide
0.1 ppb Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines, California OEHHA PHGs, EWG Tap Water Database.

Treatment plant contact info

For service issues, water quality concerns, or to request a Consumer Confidence Report from GSW&SA (SC2620004).

Treatment Plant

FacilityPLANT WELL (G26451) PERRY ROAD

ZIP codes served

CONWAY's public water systems serve the following ZIP codes: