Free tap water grades for 1,100+ water systems & 10,000+ ZIP codesFree tap water grades for 10,000+ ZIP codes Official EPA compliance records · Independent ratings

Tap Water Quality Report

Tap water quality in Lubbock, Texas

Served by LUBBOCK PUBLIC WATER SYSTEM. 275,041 residents.

Average score 57/100
Utilities 1
Population 275,041
Quick answer

Tap water in Lubbock, Texas receives a grade of F (57/100) from TapWaterSafety.org. It's served by LUBBOCK PUBLIC WATER SYSTEM. The most significant water quality concerns are: Arsenic significantly above health guideline; Haloacetic acids (HAA9) significantly above health guideline; Dibromoacetic acid significantly above health guideline. Data sources: EPA SDWIS, EPA ECHO, EWG Tap Water Database.

Data sources for this grade: utilities.csv EWG Tap Water Database ⓘ How did we get this rating?

What's in Lubbock's tap water

Top water quality concerns identified by the EPA and Environmental Working Group across the utility serving Lubbock.

Arsenic significantly above health guideline

Moderate concern

Arsenic detected at 1.96 ppb, 489x above the EWG health guideline of 0.004 ppb.

Haloacetic acids (HAA9) significantly above health guideline

Moderate concern

Haloacetic acids (HAA9) detected at 13.4 ppb, 223x above the EWG health guideline of 0.06 ppb.

Dibromoacetic acid significantly above health guideline

Moderate concern

Dibromoacetic acid detected at 4.28 ppb, 143x above the EWG health guideline of 0.03 ppb.

EPA compliance record

Official U.S. EPA records for LUBBOCK PUBLIC WATER SYSTEM (system ID TX1520002) for the last 3 years. Checked 2026-10-07.

No health-based violations. EPA recorded 3 quarters with a testing, reporting or notice violation.
3 of 12quarters with a violation
Nolead above EPA action level
08/04/2023last state inspection
RuleTypeSinceStatus
Lead and Copper Rule Revisions Missed reporting 07/02/2025 Resolved
Revised Total Coliform Rule Missed testing 01/01/2026 Resolved

Source: U.S. EPA Enforcement and Compliance History Online (ECHO), from the Safe Drinking Water Information System. See EPA's full report.

Recommended filters for Lubbock

Filters matched to the specific contaminants in Lubbock's water supply.

Reverse osmosis certified for arsenic (NSF/ANSI 58)

$429-$599

Reverse osmosis certified under NSF/ANSI 58 for arsenic is the most reliable home option.

AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, 372
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401
Editorial pick · affiliate link coming soon

Carbon filter certified for VOCs (NSF/ANSI 53)

$180-$599

Activated carbon is effective for disinfection byproducts. Look for NSF/ANSI 53 VOC reduction.

Aquasana AQ-5300 Under-Sink Filter
$180-$240 NSF 42, 53, 401, 372
Editorial pick · affiliate link coming soon
AquaTru Countertop Reverse Osmosis
$449-$599 NSF 42, 53, 58, 401, 372
Editorial pick · affiliate link coming soon
Aquasana OptimH2O Reverse Osmosis + Claryum
$429-$549 NSF 42, 53, 58, 401
Editorial pick · affiliate link coming soon

Disclosure: TapWaterSafety earns a commission from purchases made through these links. This does not influence our scoring methodology or filter selection.

All contaminants detected in Lubbock's tap water

Every contaminant identified, compared side-by-side against US EPA legal limits, the EU Drinking Water Directive (2020/2184), WHO Guidelines, and California's Public Health Goal. Why we show multiple standards →

🇪🇺
Lubbock's tap water would fail European Union drinking water standards. One or more detected contaminants exceed EU Drinking Water Directive 2020/2184 limits, even though they may be fully legal under US EPA rules. View the standards we compare against →
Contaminant Detected EWG
US health-based
EPA
US legal
EU DWD
Europe
WHO
global
CA PHG
strictest US
Tested
sample year
Status
Arsenic
Heavy metal
1.96 ppb 0.004 10.0 10 10 0.004 — 489× over
Haloacetic acids (HAA9)
Disinfection byproduct
13.4 ppb 0.06 — — — — — 223× over
Dibromoacetic acid
Disinfection byproduct
4.28 ppb 0.03 — — — — — 143× over
Bromochloroacetic acid
Disinfection byproduct
2.29 ppb 0.02 — — — — — 115× over
Total trihalomethanes (TTHMs)
Disinfection byproduct
15.8 ppb 0.15 80.0 100 — — — 105× over
Haloacetic acids (HAA5)
Disinfection byproduct
7.94 ppb 0.1 60.0 60 — — — 79× over
Dibromochloromethane
Disinfection byproduct
5.11 ppb 0.1 — — — — — 51× over
Chromium (hexavalent)
Heavy metal
0.932 ppb 0.02 — — — — — 47× over
Bromodichloromethane
Disinfection byproduct
1.67 ppb 0.06 — — — — — 28× over
Bromoform
Disinfection byproduct
8.36 ppb 0.5 — — — — — 17× over
Nitrate and nitrite
Inorganic
1.69 ppm 0.14 10.0 11.3 11.3 10 — 12× over
Dichloroacetic acid
Disinfection byproduct
1.5 ppb 0.2 — — — — — 7.5× over
Nitrate
Inorganic
0.966 ppm 0.14 10.0 11.3 11.3 10 — 6.9× over
Chlorite
Disinfection byproduct
341.2 ppb 50.0 1000.0 — — — — 6.8× over
Uranium
Radiological
2.17 pCi/L 0.43 20.0 30 30 0.43 — 5.0× over
Trichloroacetic acid
Disinfection byproduct
0.441 ppb 0.1 — — — — — 4.4× over
Chlorate
Disinfection byproduct
401.4 ppb 210.0 — — — — — 1.9× over
Chloroform
Disinfection byproduct
0.331 ppb 0.4 — — — — — Below guideline
Vanadium
Other
10.7 ppb 21.0 — — — — — Below guideline
Barium
Heavy metal
151.3 ppb 700.0 2000.0 — 1300 2000 — Below guideline
Aluminum
Heavy metal
85.7 ppb 600.0 — 200 — 600 — Below guideline
Molybdenum
Other
4.17 ppb 40.0 — — — — — Below guideline
Monobromoacetic acid
Disinfection byproduct
1.02 ppb 25.0 — — — — — Below guideline
Monochloroacetic acid
Disinfection byproduct
0.703 ppb 53.0 — — — — — Below guideline
Perfluorobutanoic Acid (PFBA)
PFAS
4.15 ppt 1000.0 — — — — — Below guideline
Strontium
Radiological
1.13 ppb 1500.0 — — — — — Below guideline
Manganese
Heavy metal
0.0482 ppb 100.0 — 50 80 — — Below guideline
Chromium (total)
Heavy metal
2.66 ppb — 100.0 — — — — Below guideline
Cyanide
Inorganic
93.2 ppb — 200.0 50 70 150 — Fails EU
Fluoride
Inorganic
0.885 ppm — 4.0 1.5 1.5 — — Below guideline
Lithium
Other
40.8 ppb — — — — — — Below guideline
Quinoline
Other
0.00201 ppb — — — — — — Below guideline

All values in the unit of the detected level. Red cells indicate the detected level exceeds that standard. Some contaminants have limits in some jurisdictions but not others (shown as —). The "Tested" column shows the year each contaminant sample was collected.

Sources: US EPA, EU Drinking Water Directive 2020/2184, WHO Guidelines, California OEHHA PHGs, EWG Tap Water Database.

Treatment plant contact info

For service issues, water quality concerns, or to request a Consumer Confidence Report from LUBBOCK PUBLIC WATER SYSTEM.

Treatment Plant

FacilityPLANT - BAILEY CO SANDHILLS